How to Select a High Pressure Pump for Containerized SWRO Systems

Two containerized SWRO systems with the same daily water production can need very different high-pressure pump flow rates. The difference often comes from the energy recovery arrangement: in one system, all membrane feed passes through the main pump; in another, an isobaric pressure exchanger pressurizes a large share of the feed.

Before choosing a pump, establish how much water the membranes need each hour, how that flow reaches them, and the pressure required under the site’s seawater conditions. These determine the pump displacement, operating speed and motor duty. The container layout then determines whether the assembly can be installed, cooled and serviced properly.

pumps with motor (1)

How the ERD arrangement changes high-pressure pump flow

After pretreatment and cartridge filtration, the seawater supply has to maintain the required pressure at the high-pressure pump inlet. Downstream, the membranes divide the feed into permeate and concentrate. Recovery is the proportion of membrane feed that becomes permeate, so the basic flow balance is:

Membrane feed flow = permeate flow ÷ recovery
Concentrate flow = membrane feed flow − permeate flow

This gives the flow entering the membrane array. Whether the main high-pressure pump supplies all of it depends on the piping arrangement.

Without energy recovery

When there is no ERD and all feed passes through the main high-pressure pump, the pump supplies the full membrane feed flow. At 40% recovery, each 1 m³/h of permeate requires 2.5 m³/h of membrane feed. The remaining 1.5 m³/h leaves the membranes as concentrate.

With a turbine-type ERD

A hydraulic turbocharger uses the high-pressure concentrate to drive a turbine connected to a pump impeller. The impeller adds pressure to the feed stream. In a common arrangement with the turbocharger downstream of the main high-pressure pump, the main pump still handles the full membrane feed flow, while the turbocharger supplies part of the required pressure rise. Energy Recovery’s turbocharger description explains this transfer through the common shaft.

A turbine mechanically coupled to the main pump can instead reduce the external shaft power required. In either arrangement, calculate the recovered pressure or power at the actual concentrate flow. The presence of an ERD alone does not define the main pump duty.

With an isobaric pressure exchanger

An isobaric ERD transfers pressure directly from the concentrate to a separate stream of incoming seawater. That pressurized stream joins the discharge from the main high-pressure pump before entering the membranes. A circulation or booster pump in the ERD loop makes up the pressure losses through the membrane array, pressure exchanger and connecting pipework; some ERDs integrate this booster.

In this flow arrangement, the main high-pressure pump supplies approximately the permeate flow, plus the ERD’s internal leakage and any other losses leaving the high-pressure circuit. The ERD branch supplies most of the remaining membrane feed. The PX pressure-exchanger flow diagram shows the two feed paths.

The main pump, ERD and circulation pump therefore have separate duties. The membrane feed flow cannot simply be copied into all three equipment schedules.

Flow calculations for 200–1,500 m³/day SWRO systems

For a system producing 500 m³/day over 24 operating hours, the permeate flow is 20.8 m³/h. At 40% recovery, the membranes need 52.1 m³/h of feed and discharge 31.3 m³/h of concentrate. A layout sending all feed through the main pump needs approximately 52.1 m³/h from that pump. In a typical isobaric layout, the main pump starts from 20.8 m³/h, with the specific ERD’s leakage allowance added to the selection.

The following calculations assume 24 hours of membrane operation per day and 40–45% recovery. Daily capacity here means membrane permeate production; if the requirement is net usable water after flushing or other plant consumption, include that extra production in the water balance.

Permeate production
(m³/day)
Permeate flow
(m³/h)
Membrane feed at 40–45% recovery
(m³/h)
Main HP pump with an isobaric ERD
(m³/h)
2008.318.5–20.88.3 + ERD losses
50020.846.3–52.120.8 + ERD losses
1,00041.792.6–104.241.7 + ERD losses
1,50062.5138.9–156.362.5 + ERD losses

For a layout where the full feed passes through the main pump, use the membrane-feed column as the starting flow duty. For an isobaric layout, use the permeate flow plus the ERD-specific losses for the main pump, then size the ERD branch separately. The final pump flow comes from the selected equipment’s flow balance.

Operating hours make a substantial difference. Producing 500 m³/day in 20 hours requires 25.0 m³/h of permeate and, at 40% recovery, 62.5 m³/h of membrane feed. For parallel trains, divide the production between the trains actually operating; a standby train does not contribute to normal production.

Set pressure and motor power from the membrane design

Daily production does not determine the required pressure. Use the membrane projection for the seawater salinity, temperature, recovery and membrane condition expected at the site. Higher salinity and colder water can increase the pressure needed to maintain production. Membrane aging and fouling allowances also belong in that calculation.

Then translate the membrane inlet pressure into the duty at the pump ports. In a direct-feed or isobaric arrangement, the main pump discharge must cover the membrane inlet pressure and the losses between the pump and membrane inlet. With a downstream turbocharger, its pressure contribution changes the pressure required from the main pump. The motor calculation uses the pump’s own differential pressure: outlet pressure minus inlet pressure.

Hydraulic power (kW) = pump flow (m³/h) × differential pressure (bar) ÷ 36

Divide hydraulic power by the pump efficiency at that duty to obtain shaft power, allowing for any drive losses when selecting the motor. Check the highest required shaft power across the operating range, together with starting torque and the available electrical supply. A smaller main-pump flow in an isobaric layout changes its motor duty substantially, even when membrane pressure remains similar.

For Rohre HPS pumps, the published maximum outlet pressure is up to 85 barg. The selected model must meet the required continuous duty within its pressure, speed, temperature and inlet limits. Piping, valves, pressure vessels and the ERD also need suitable ratings. Hydrostatic test pressure is a separate value and cannot be used as an operating allowance.

Choose displacement and speed together

An axial piston pump displaces a volume of water each revolution, so its delivered flow is approximately proportional to shaft speed. Actual delivery also depends on internal leakage, water temperature and pressure. Use the selected model’s flow curve at the required duty rather than its model number alone.

A VFD is useful when production changes, when the system needs a controlled ramp, or when flow must be trimmed during commissioning. Its usable range has to stay within both the pump’s permitted operating speeds and the motor’s torque and cooling limits. Selecting a large pump and slowing it far below its permitted range does not provide useful operating flexibility.

Fixed-speed operation can also suit a defined duty. The displacement must match the required flow at the motor’s actual loaded speed, and the system still needs a suitable starting, pressure-control and shutdown arrangement. Parallel pump systems can combine fixed-speed units with a variable-speed unit where the required adjustment range supports that approach.

Speed mainly changes the flow from a positive-displacement pump; the hydraulic circuit determines the resulting pressure. Pressure control therefore has to be coordinated with recovery, concentrate flow and the ERD. It cannot rely on changing pump speed without considering the rest of the flow balance.

HPS 22~39 Typical Flow Curve at Maximum Pressure.029

Compare pump technologies at the actual duty

Axial piston pumps are well suited to compact SWRO packages where high pressure, limited installation space and flow adjustment matter. Their displacement-based flow makes speed selection straightforward, provided the inlet supply and operating limits are respected. The Rohre HPS model tables and flow curves allow the required duty to be checked against individual pump sizes.

Multistage centrifugal pumps are also used in SWRO. Compare their efficiency, minimum flow and allowable operating region across the expected duties. A technology choice needs the actual flow and pressure range, the ERD arrangement and the number of operating pumps; container installation alone does not establish which pump will use less energy.

Compare total electrical consumption at the same permeate production, recovery and membrane conditions. Include the main pump, ERD booster or circulation pump, seawater supply pump, motors and drives. Main-pump efficiency on its own does not describe the energy consumption of the complete SWRO train.

pumps with motor (6)

Match seawater materials to the operating conditions

Rohre HPS pumps use 2205 duplex stainless steel housings and 2507 super duplex stainless steel internal wetted metal components as the standard configuration. These are distinct material specifications; a 2507 internal component does not make the housing 2507.

Material selection also depends on seawater temperature, chloride concentration, cleaning chemicals and periods of stagnation. The wetted valves, fittings, seals and pipework need the same review. Inside a coastal container, salt-laden air and condensation also affect motor enclosures, electrical equipment and external fasteners.

Maintain the inlet supply during operation and flushing

Measure inlet pressure at the pump, downstream of the cartridge filter. A pressure reading upstream of a clean filter does not show what reaches the pump when the filter loads up. Size the supply pump and pipework for the required flow with the filter and line losses included. In an isobaric system, the low-pressure supply may also feed the ERD branch, so its total duty can be much greater than the main high-pressure pump flow.

If the available supply cannot maintain the selected HPS model’s inlet requirement, an upstream booster pump may be needed. Low inlet pressure, air ingress and inadequate filtration can damage a water-lubricated axial piston pump. Locate the inlet pressure measurement and protective interlocks where they can detect the condition at the pump.

A positive-displacement pump also needs an appropriately sized pressure-relief path that remains available if the downstream flow is blocked. Size it for the pump’s maximum possible delivery and coordinate the set pressure with the lowest applicable equipment limit. A pressure alarm or motor trip does not replace the relief device.

Plan the flushing route together with the operating route. The flush supply must reach the membrane and ERD circuits that need desalting, while maintaining the pump’s permitted pressure relationships and lubrication conditions. Depressurization and non-return arrangements have to prevent damaging reverse flow or reverse rotation.

The membrane CIP loop has its own circulation duty. Decide from the piping diagram whether cleaning solution passes through the high-pressure pump or bypasses it, and check chemical, temperature and seal compatibility before including the pump in that route. The Rohre axial piston pump installation and maintenance manual covers the pump’s installation and operating requirements.

Leave space to install and service the pump assembly

A pump-and-motor assembly has to remain accessible after the membranes, filters, piping and electrical cabinets are installed. Allow room to inspect connections, align the coupling, remove the motor or pump, and bring service equipment through the container opening. Include the weight and lifting route in the layout.

Support the pipework independently so its weight and misalignment do not load the pump ports. Select hoses and vibration isolation for the actual pressure and seawater service. Motor and VFD heat must also be removed from the container at the site’s ambient temperature.

For modular expansion, establish the flow and pressure duty of each train before standardizing pumps and spares. Different daily capacities may need different pump counts or speeds. The RO pump types and service-life guide discusses how the feed, high-pressure and cleaning pumps serve different parts of the plant.

Review your SWRO pump duty with Rohre

Send us the membrane design flow and pressure, expected seawater conditions, operating hours, and the ERD model or piping diagram. Include the minimum pressure available at the pump inlet and the electrical supply. We can use these to review the HPS pump size, operating speed and motor duty for your container layout. Contact the Rohre pump team with your design details.